<rdf:RDF xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcat="http://www.w3.org/ns/dcat#" xmlns:dct="http://purl.org/dc/terms/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#">
  <rdf:Description rdf:about="https://doi.org/10.1002/rcm.8478">
    <dct:isReferencedBy>CORDIS</dct:isReferencedBy>
    <dct:isReferencedBy>OpenAire</dct:isReferencedBy>
    <dct:isReferencedBy>Research@WUR</dct:isReferencedBy>
    <dct:isReferencedBy>Sygma</dct:isReferencedBy>
    <dct:isReferencedBy>Bielefeld Academic Search Engine (BASE)</dct:isReferencedBy>
    <dct:isReferencedBy>Pure Utrecht University</dct:isReferencedBy>
    <dct:isReferencedBy>G&#246;ttingen Research Online Publications</dct:isReferencedBy>
    <dct:isReferencedBy>Publikationenserver der Georg-August-Universit&#228;t G&#246;ttingen</dct:isReferencedBy>
    <dct:isReferencedBy>Crossref</dct:isReferencedBy>
    <dct:isReferencedBy>Microsoft Academic Graph</dct:isReferencedBy>
    <dct:isReferencedBy>Europe PubMed Central</dct:isReferencedBy>
    <dct:isReferencedBy>University of Groningen Research Portal</dct:isReferencedBy>
    <dct:isReferencedBy>UnpayWall</dct:isReferencedBy>
    <dct:isReferencedBy>PubMed Central</dct:isReferencedBy>
    <dct:isReferencedBy>European Union Open Data Portal</dct:isReferencedBy>
    <dct:references>https://onlinelibrary.wiley.com/doi/pdf/10.1002/rcm.8478</dct:references>
    <dct:references>https://doi.org/10.1002/rcm.8478</dct:references>
    <dcat:downloadURL rdf:resource="https://onlinelibrary.wiley.com/doi/pdf/10.1002/rcm.8478"/>
    <dct:isPartOf>Rapid Communications in Mass Spectrometry</dct:isPartOf>
    <dct:license>Open Access</dct:license>
    <dct:created>2019-05-07</dct:created>
    <dc:description>Rationale&lt;p&gt;Determination of &#65486;&#65460;17O values directly from CO2 with traditional gas source isotope ratio mass spectrometry is not possible due to isobaric interference of 13C16O16O on 12C17O16O. The methods developed so far use either chemical conversion or isotope equilibration to determine the &#65486;&#65460;17O value of CO2. In addition, &#65486;&#65460;13C measurements require correction for the interference from 12C17O16O on 13C16O16O since it is not possible to resolve the two isotopologues.&lt;/p&gt;Methods&lt;p&gt;We present a technique to determine the &#65486;&#65460;17O, &#65486;&#65460;18O and &#65486;&#65460;13C values of CO2 from the fragment ions that are formed upon electron ionization in the ion source of the Thermo Scientific 253 Ultra high&#65506;&#65408;&#65424;resolution isotope ratio mass spectrometer (hereafter 253 Ultra). The new technique is compared with the CO2&#65506;&#65408;&#65424;O2 exchange method and the 17O&#65506;&#65408;&#65424;correction algorithm for &#65486;&#65460;17O and &#65486;&#65460;13C values, respectively.&lt;/p&gt;Results&lt;p&gt;The scale contractions for &#65486;&#65460;13C and &#65486;&#65460;18O values are slightly larger for fragment ion measurements than for molecular ion measurements. The &#65486;&#65460;17O and &#65486;&#65428;17O values of CO2 can be measured on the 17O+ fragment with an internal error that is a factor 1&#65506;&#65408;&#65427;2 above the counting statistics limit. The ultimate precision depends on the signal intensity and on the total time that the 17O+ beam is monitored; a precision of 14&#65506;&#65408;&#65417;ppm (parts per million) (standard error of the mean) was achieved in 20&#65506;&#65408;&#65417;hours at the University of G&#65475;&#65462;ttingen. The &#65486;&#65428;17O measurements with the O&#65506;&#65408;&#65424;fragment method agree with the CO2&#65506;&#65408;&#65424;O2 exchange method over a range of &#65486;&#65428;17O values of &#65506;&#65416;&#65426;0.3 to +0.7&#65506;&#65408;&#65456;.&lt;/p&gt;Conclusions&lt;p&gt;Isotope measurements on atom fragment ions of CO2 can be used as an alternative method to determine the carbon and oxygen isotopic composition of CO2 without chemical processing or corrections for mass interferences.&lt;/p&gt;</dc:description>
    <dc:subject>550</dc:subject>
    <dc:subject>NITROUS-OXIDE</dc:subject>
    <dc:subject>O-17/O-16</dc:subject>
    <dc:subject>ANALYTICAL SYSTEM</dc:subject>
    <dc:subject>01 natural sciences</dc:subject>
    <dc:subject>O-2</dc:subject>
    <dc:subject>0104 chemical sciences</dc:subject>
    <dc:subject>O-17 CORRECTION</dc:subject>
    <dc:subject>HIGH-PRECISION MEASUREMENTS</dc:subject>
    <dc:subject>13. Climate action</dc:subject>
    <dc:subject>Life Science</dc:subject>
    <dc:subject>ABUNDANCE</dc:subject>
    <dc:subject>DELTA-O-17</dc:subject>
    <dc:subject>EXCHANGE</dc:subject>
    <dc:subject>DIOXIDE</dc:subject>
    <dc:subject>Research Articles</dc:subject>
    <dc:subject>0105 earth and related environmental sciences</dc:subject>
    <dc:creator rdf:resource="https://orcid.org/0000-0002-2275-0713"/>
    <dc:creator rdf:resource="https://orcid.org/0000-0003-1875-8314"/>
    <dc:creator rdf:resource="https://orcid.org/0000-0002-2640-8122"/>
    <dc:creator rdf:resource="https://orcid.org/0000-0002-2618-2768"/>
    <dc:creator rdf:resource="https://orcid.org/0000-0002-6688-8968"/>
    <dc:creator>Wouter Peters, Wouter Peters, Jakub Surma, Gerbrand Koren, Nina Albrecht, Magdalena E. G. Hofmann, Amzad H. Laskar, Dipayan Paul, Dipayan Paul, Johannes Schwieters, Andreas Pack, Getachew A. Adnew, Thomas R&#246;ckmann, </dc:creator>
    <dc:date>2019-08-05</dc:date>
    <dc:type>journalpaper</dc:type>
    <dct:abstract>Rationale&lt;p&gt;Determination of &#65486;&#65460;17O values directly from CO2 with traditional gas source isotope ratio mass spectrometry is not possible due to isobaric interference of 13C16O16O on 12C17O16O. The methods developed so far use either chemical conversion or isotope equilibration to determine the &#65486;&#65460;17O value of CO2. In addition, &#65486;&#65460;13C measurements require correction for the interference from 12C17O16O on 13C16O16O since it is not possible to resolve the two isotopologues.&lt;/p&gt;Methods&lt;p&gt;We present a technique to determine the &#65486;&#65460;17O, &#65486;&#65460;18O and &#65486;&#65460;13C values of CO2 from the fragment ions that are formed upon electron ionization in the ion source of the Thermo Scientific 253 Ultra high&#65506;&#65408;&#65424;resolution isotope ratio mass spectrometer (hereafter 253 Ultra). The new technique is compared with the CO2&#65506;&#65408;&#65424;O2 exchange method and the 17O&#65506;&#65408;&#65424;correction algorithm for &#65486;&#65460;17O and &#65486;&#65460;13C values, respectively.&lt;/p&gt;Results&lt;p&gt;The scale contractions for &#65486;&#65460;13C and &#65486;&#65460;18O values are slightly larger for fragment ion measurements than for molecular ion measurements. The &#65486;&#65460;17O and &#65486;&#65428;17O values of CO2 can be measured on the 17O+ fragment with an internal error that is a factor 1&#65506;&#65408;&#65427;2 above the counting statistics limit. The ultimate precision depends on the signal intensity and on the total time that the 17O+ beam is monitored; a precision of 14&#65506;&#65408;&#65417;ppm (parts per million) (standard error of the mean) was achieved in 20&#65506;&#65408;&#65417;hours at the University of G&#65475;&#65462;ttingen. The &#65486;&#65428;17O measurements with the O&#65506;&#65408;&#65424;fragment method agree with the CO2&#65506;&#65408;&#65424;O2 exchange method over a range of &#65486;&#65428;17O values of &#65506;&#65416;&#65426;0.3 to +0.7&#65506;&#65408;&#65456;.&lt;/p&gt;Conclusions&lt;p&gt;Isotope measurements on atom fragment ions of CO2 can be used as an alternative method to determine the carbon and oxygen isotopic composition of CO2 without chemical processing or corrections for mass interferences.&lt;/p&gt;</dct:abstract>
    <dc:title>Determination of the triple oxygen and carbon isotopic composition of CO 2 from atomic ion fragments formed in the ion source of the 253 Ultra high&#8208;resolution isotope ratio mass spectrometer</dc:title>
    <dc:identifier>10.1002/rcm.8478</dc:identifier>
  </rdf:Description>
</rdf:RDF>