<rdf:RDF xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dct="http://purl.org/dc/terms/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#">
  <rdf:Description rdf:about="https://doi.org/10.1016/j.radmeas.2018.06.008">
    <dct:isReferencedBy>CORDIS</dct:isReferencedBy>
    <dct:isReferencedBy>OpenAire</dct:isReferencedBy>
    <dct:isReferencedBy>Sygma</dct:isReferencedBy>
    <dct:isReferencedBy>Online Research Database In Technology</dct:isReferencedBy>
    <dct:isReferencedBy>Theses@asb</dct:isReferencedBy>
    <dct:isReferencedBy>UnpayWall</dct:isReferencedBy>
    <dct:isReferencedBy>ZENODO</dct:isReferencedBy>
    <dct:isReferencedBy>PURE Aarhus University</dct:isReferencedBy>
    <dct:isReferencedBy>Crossref</dct:isReferencedBy>
    <dct:isReferencedBy>Microsoft Academic Graph</dct:isReferencedBy>
    <dct:isReferencedBy>European Union Open Data Portal</dct:isReferencedBy>
    <dct:isPartOf>Radiation Measurements</dct:isPartOf>
    <dct:license>Open Access</dct:license>
    <dct:created>2018-06-05</dct:created>
    <dc:description>Abstract   There is evidence that optically stimulated luminescence (OSL) dating of quartz using the single-aliquot regenerative-dose (SAR) protocol underestimates the equivalent dose (De) for paleodoses above 100&#8211;200&#8239;Gy. Additionally, &#8216;infinitely&#8217; old samples found not to be in laboratory saturation were reported. We present single and multi-grain SAR-OSL investigations for a coarse-grained (180&#8211;250&#8239;&#956;m) quartz sample extracted from loess collected below the Brunhes/Matuyama transition at the Roksolany site (Ukraine). The sample was dated to more than 1000 ka by electron spin resonance using a multi center approach (Al and Ti signals), confirming that the De (&#8764;2000&#8239;Gy) falls beyond the limit of standard OSL De measurement techniques. However, the natural signal measured using multi-grain aliquots of quartz was found to be below the laboratory saturation level. A comparison was made between synthetic dose response curves (DRCs) generated from single-grain and multi-grain aliquot data, respectively; the natural signal was found to be closer to the latoratory saturation level (92%) in the case of the single-grain synthetic DRC than for the multi-grain synthetic DRC where the signal was 86% of the saturation level. This difference could not be attributed to stimulation with different wavelengths, i.e. blue and green light stimulation for multi and single-grain measurements, respectively. By analysing synthetic data obtained by grouping grains according to their brightness, it was observed that brighter grains give a natural signal closer to the laboratory saturation level. This trend was confirmed for multi-grain aliquot data. Based on these findings we infer that variability in the contribution from populations of grains with different levels of brightness may represent a controlling factor in the closeness of the natural signal to laboratory saturation level for infinitely old samples.</dc:description>
    <dc:subject>Multi-grain aliquots</dc:subject>
    <dc:subject>03 medical and health sciences</dc:subject>
    <dc:subject>0302 clinical medicine</dc:subject>
    <dc:subject>Quartz dose response</dc:subject>
    <dc:subject>&#8216;Infinitely&#8217; old</dc:subject>
    <dc:subject>Optically stimulated luminescence (OSL)</dc:subject>
    <dc:subject>Saturation</dc:subject>
    <dc:subject>Single grains</dc:subject>
    <dc:subject>01 natural sciences</dc:subject>
    <dc:subject>0105 earth and related environmental sciences</dc:subject>
    <dc:creator rdf:resource="https://orcid.org/0000-0003-4799-3866"/>
    <dc:creator rdf:resource="https://orcid.org/0000-0001-5559-1862"/>
    <dc:creator rdf:resource="https://orcid.org/0000-0003-0587-8077"/>
    <dc:creator rdf:resource="https://orcid.org/0000-0002-8942-7566"/>
    <dc:creator rdf:resource="https://orcid.org/0000-0002-5772-5294"/>
    <dc:creator rdf:resource="https://orcid.org/0000-0002-4883-1220"/>
    <dc:creator>Alida Timar-Gabor, Andrew S. Murray, Jan-Pieter Buylaert, Jan-Pieter Buylaert, Valentina Anechitei-Deacu, Mayank Jain, M. Bailey, Kristina J&#248;rkov Thomsen, </dc:creator>
    <dc:date>2018-12-01</dc:date>
    <dc:type>journalpaper</dc:type>
    <dct:abstract>Abstract   There is evidence that optically stimulated luminescence (OSL) dating of quartz using the single-aliquot regenerative-dose (SAR) protocol underestimates the equivalent dose (De) for paleodoses above 100&#8211;200&#8239;Gy. Additionally, &#8216;infinitely&#8217; old samples found not to be in laboratory saturation were reported. We present single and multi-grain SAR-OSL investigations for a coarse-grained (180&#8211;250&#8239;&#956;m) quartz sample extracted from loess collected below the Brunhes/Matuyama transition at the Roksolany site (Ukraine). The sample was dated to more than 1000 ka by electron spin resonance using a multi center approach (Al and Ti signals), confirming that the De (&#8764;2000&#8239;Gy) falls beyond the limit of standard OSL De measurement techniques. However, the natural signal measured using multi-grain aliquots of quartz was found to be below the laboratory saturation level. A comparison was made between synthetic dose response curves (DRCs) generated from single-grain and multi-grain aliquot data, respectively; the natural signal was found to be closer to the latoratory saturation level (92%) in the case of the single-grain synthetic DRC than for the multi-grain synthetic DRC where the signal was 86% of the saturation level. This difference could not be attributed to stimulation with different wavelengths, i.e. blue and green light stimulation for multi and single-grain measurements, respectively. By analysing synthetic data obtained by grouping grains according to their brightness, it was observed that brighter grains give a natural signal closer to the laboratory saturation level. This trend was confirmed for multi-grain aliquot data. Based on these findings we infer that variability in the contribution from populations of grains with different levels of brightness may represent a controlling factor in the closeness of the natural signal to laboratory saturation level for infinitely old samples.</dct:abstract>
    <dc:title>Single and multi-grain OSL investigations in the high dose range using coarse quartz</dc:title>
    <dc:identifier>10.1016/j.radmeas.2018.06.008</dc:identifier>
    <dct:references>https://doi.org/10.1016/j.radmeas.2018.06.008</dct:references>
  </rdf:Description>
</rdf:RDF>