<rdf:RDF xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dct="http://purl.org/dc/terms/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#">
  <rdf:Description rdf:about="https://doi.org/10.1063/5.0022170">
    <dct:isReferencedBy>OPENAIRE</dct:isReferencedBy>
    <dct:isReferencedBy>OpenAire</dct:isReferencedBy>
    <dct:isReferencedBy>Crossref</dct:isReferencedBy>
    <dct:isReferencedBy>Microsoft Academic Graph</dct:isReferencedBy>
    <dct:isPartOf>Applied Physics Letters</dct:isPartOf>
    <dct:license>Closed Access</dct:license>
    <dct:created>2020-10-13</dct:created>
    <dc:description>&lt;?xml version='1.0' encoding='UTF-8'?&gt;&lt;article&gt;&lt;p&gt;Ion implantation-induced effects were studied in Ge implanted &#946;-Ga2O3 with the fluence and energy of 3&#8201;&#215;&#8201;1013&#8201;cm&#8722;2/60&#8201;keV, 5&#8201;&#215;&#8201;1013&#8201;cm&#8722;2/100&#8201;keV, and 7&#8201;&#215;&#8201;1013&#8201;cm&#8722;2/200&#8201;keV using analytical electron microscopy via scanning/transmission electron microscopy, electron energy loss spectroscopy, and precession electron diffraction via TopSpin. Imaging shows an isolated band of damage after Ge implantation, which extends &#8764;130&#8201;nm from the sample surface and corresponds to the projected range of the ions. Electron diffraction demonstrates that the entirety of the damage band is the &#954; phase, indicating an implantation-induced phase transition from &#946; to &#954;-Ga2O3. Post-implantation annealing at 1150&#8201;&#176;C for 60 s under the O2 atmosphere led to a back transformation of &#954; to &#946;; however, an &#8764;17&#8201;nm damage zone remained at the sample surface. Despite the back transformation from &#954; to &#946; with annealing, O K-edge spectra show changes in the fine structure between the pristine, implanted, and implanted-annealed samples, and topspin strain analysis shows a change in strain between the two samples. These data indicate differences in the electronic/chemical structure, where the change of the oxygen environment extended beyond the implantation zone (&#8764;130&#8201;nm) due to the diffusion of Ge into the bulk material, which, in turn, causes a tensile strain of 0.5%. This work provides a foundation for understanding of the effects of ion implantation on defect/phase evolution in &#946;-Ga2O3 and the related recovery mechanism, opening a window toward building a reliable device for targeted applications.&lt;/p&gt;&lt;/article&gt;</dc:description>
    <dc:subject>0103 physical sciences</dc:subject>
    <dc:subject>02 engineering and technology</dc:subject>
    <dc:subject>0210 nano-technology</dc:subject>
    <dc:subject>01 natural sciences</dc:subject>
    <dc:creator rdf:resource="https://orcid.org/0000-0001-7808-7036"/>
    <dc:creator rdf:resource="https://orcid.org/0000-0002-0993-6134"/>
    <dc:creator rdf:resource="https://orcid.org/0000-0002-3840-8357"/>
    <dc:creator rdf:resource="https://orcid.org/0000-0001-6498-1256"/>
    <dc:creator rdf:resource="https://orcid.org/0000-0001-5349-1411"/>
    <dc:creator>Elaf A. Anber, Daniel Foley, Andrew C. Lang, James Nathaniel, James L. Hart, Marko J. Tadjer, Karl D. Hobart, Stephen Pearton, Mitra L. Taheri, </dc:creator>
    <dc:date>2020-10-12</dc:date>
    <dc:type>journalpaper</dc:type>
    <dct:abstract>&lt;?xml version='1.0' encoding='UTF-8'?&gt;&lt;article&gt;&lt;p&gt;Ion implantation-induced effects were studied in Ge implanted &#946;-Ga2O3 with the fluence and energy of 3&#8201;&#215;&#8201;1013&#8201;cm&#8722;2/60&#8201;keV, 5&#8201;&#215;&#8201;1013&#8201;cm&#8722;2/100&#8201;keV, and 7&#8201;&#215;&#8201;1013&#8201;cm&#8722;2/200&#8201;keV using analytical electron microscopy via scanning/transmission electron microscopy, electron energy loss spectroscopy, and precession electron diffraction via TopSpin. Imaging shows an isolated band of damage after Ge implantation, which extends &#8764;130&#8201;nm from the sample surface and corresponds to the projected range of the ions. Electron diffraction demonstrates that the entirety of the damage band is the &#954; phase, indicating an implantation-induced phase transition from &#946; to &#954;-Ga2O3. Post-implantation annealing at 1150&#8201;&#176;C for 60 s under the O2 atmosphere led to a back transformation of &#954; to &#946;; however, an &#8764;17&#8201;nm damage zone remained at the sample surface. Despite the back transformation from &#954; to &#946; with annealing, O K-edge spectra show changes in the fine structure between the pristine, implanted, and implanted-annealed samples, and topspin strain analysis shows a change in strain between the two samples. These data indicate differences in the electronic/chemical structure, where the change of the oxygen environment extended beyond the implantation zone (&#8764;130&#8201;nm) due to the diffusion of Ge into the bulk material, which, in turn, causes a tensile strain of 0.5%. This work provides a foundation for understanding of the effects of ion implantation on defect/phase evolution in &#946;-Ga2O3 and the related recovery mechanism, opening a window toward building a reliable device for targeted applications.&lt;/p&gt;&lt;/article&gt;</dct:abstract>
    <dc:title>Structural transition and recovery of Ge implanted                       &#946;                   -Ga2O3</dc:title>
    <dc:identifier>10.1063/5.0022170</dc:identifier>
    <dct:references>https://doi.org/10.1063/5.0022170</dct:references>
  </rdf:Description>
</rdf:RDF>