Journal article

Membrane distillation as a second stage treatment of hydrothermal liquefaction wastewater after ultrafiltration

The aim of this study is the utilization of membrane distillation (MD) in the treatment of hydrothermal liquefaction wastewater (HTL-WW) to recover ammonium in the condensate. Experiments were carried out using MD under air���gap configuration with HTL-WW pretreated via Ultrafiltration. The results showed membrane stability in long-term operations, up to 36 days and through a wide range of feed temperatures, from 30 ��C to 60 ��C (Coolant temperature was kept at 20 ��C). Feed temperatures, 50 ��C and 60 ��C provided the best condensate quality, defined by high ammonium concentrations, up to 12 g/L (for 60 ��C feed temperature), and low impurity (low contamination by TOC) based on the highest NH4+:TOC ratio of 13 (for 50 ��C feed temperature). Furthermore, since flux experienced an exponential growth with the increase of feed temperature, 60 ��C was chosen as the optimal temperature to expand the study on membrane/condensate recovery, which was performed until 80%. From observational and several analytical methods, wetting was unavoidable above 60% recovery and the cause was credited to organic fouling, mainly via surfactants��� adsorption on the membrane surface. This decreased the membrane hydrophobicity, and eventually led to the progressive wetting of the membrane at 80% recovery.

Temporal

Created: 2021-12-24
Updated: 2026-10-06T16:21:42Z
Temporal extent: date

License: Unknown

Language: Unknown
Updated: 2026-10-06