{"type": "FeatureCollection", "features": [{"id": "10.1016/j.bios.2021.113890", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:15:47Z", "type": "Journal Article", "created": "2021-12-16", "title": "Real-time detection of ochratoxin A in wine through insight of aptamer conformation in conjunction with graphene field-effect transistor", "description": "Mycotoxins comprise a frequent type of toxins present in food and feed. The problem of mycotoxin contamination has been recently aggravated due to the increased complexity of the farm-to-fork chains, resulting in negative effects on human and animal health and, consequently, economics. The easy-to-use, on-site, on-demand, and rapid monitoring of mycotoxins in food/feed is highly desired. In this work, we report on an advanced mycotoxin biosensor based on an array of graphene field-effect transistors integrated on a single silicon chip. A specifically designed aptamer against Ochratoxin A (OTA) was used as a recognition element, where it was covalently attached to graphene surface via pyrenebutanoic acid, succinimidyl ester (PBASE) chemistry. Namely, an electric field stimulation was used to promote more efficient \u03c0-\u03c0 stacking of PBASE to graphene. The specific G-rich aptamer strand suggest its \u03c0-\u03c0 stacking on graphene in free-standing regime and reconfiguration in G-quadruplex during binding an OTA molecule. This realistic behavior of the aptamer is sensitive to the ionic strength of the analyte solution, demonstrating a 10-fold increase in sensitivity at low ionic strengths. The graphene-aptamer sensors reported here demonstrate fast assay with the lowest detection limit of 1.4 pM for OTA within a response time as low as 10 s, which is more than 30 times faster compared to any other reported aptamer-based methods for mycotoxin detection. The sensors hold comparable performance when operated in real-time within a complex matrix of wine without additional time-consuming pre-treatment.", "keywords": ["Condensed Matter - Materials Science", "Condensed Matter - Mesoscale and Nanoscale Physics", "Materials Science (cond-mat.mtrl-sci)", "FOS: Physical sciences", "Wine", "Biosensing Techniques", "02 engineering and technology", "Aptamers", " Nucleotide", "Ochratoxins", "01 natural sciences", "3. Good health", "0104 chemical sciences", "Limit of Detection", "Mesoscale and Nanoscale Physics (cond-mat.mes-hall)", "Animals", "Humans", "Graphite", "0210 nano-technology"]}, "links": [{"href": "https://doi.org/10.1016/j.bios.2021.113890"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Biosensors%20and%20Bioelectronics", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "10.1016/j.bios.2021.113890", "name": "item", "description": "10.1016/j.bios.2021.113890", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/10.1016/j.bios.2021.113890"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2022-03-01T00:00:00Z"}}, {"id": "10.3390/bios14050215", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:19:37Z", "type": "Journal Article", "created": "2024-04-26", "title": "Comparative Study of Field-Effect Transistors Based on Graphene Oxide and CVD Graphene in Highly Sensitive NT-proBNP Aptasensors", "description": "<?xml version='1.0' encoding='UTF-8'?><article><p>Graphene-based materials are actively being investigated as sensing elements for the detection of different analytes. Both graphene grown by chemical vapor deposition (CVD) and graphene oxide (GO) produced by the modified Hummers\u2019 method are actively used in the development of biosensors. The production costs of CVD graphene- and GO-based sensors are similar; however, the question remains regarding the most efficient graphene-based material for the construction of point-of-care diagnostic devices. To this end, in this work, we compare CVD graphene aptasensors with the aptasensors based on reduced GO (rGO) for their capabilities in the detection of NT-proBNP, which serves as the gold standard biomarker for heart failure. Both types of aptasensors were developed using commercial gold interdigitated electrodes (IDEs) with either CVD graphene or GO formed on top as a channel of liquid-gated field-effect transistor (FET), yielding GFET and rGO-FET sensors, respectively. The functional properties of the two types of aptasensors were compared. Both demonstrate good dynamic range from 10 fg/mL to 100 pg/mL. The limit of detection for NT-proBNP in artificial saliva was 100 fg/mL and 1 pg/mL for rGO-FET- and GFET-based aptasensors, respectively. While CVD GFET demonstrates less variations in parameters, higher sensitivity was demonstrated by the rGO-FET due to its higher roughness and larger bandgap. The demonstrated low cost and scalability of technology for both types of graphene-based aptasensors may be applicable for the development of different graphene-based biosensors for rapid, stable, on-site, and highly sensitive detection of diverse biochemical markers.</p></article>", "keywords": ["Transistors", " Electronic", "graphene", "field-effect transistor", "heart failure", "aptamer", "Biosensing Techniques", "02 engineering and technology", "Aptamers", " Nucleotide", "01 natural sciences", "point-of-care diagnostic", "Article", "Peptide Fragments", "0104 chemical sciences", "Limit of Detection", "Natriuretic Peptide", " Brain", "graphene oxide", "Humans", "Graphite", "Gold", "0210 nano-technology", "Electrodes", "TP248.13-248.65", "Biomarkers", "Biotechnology"]}, "links": [{"href": "https://www.mdpi.com/2079-6374/14/5/215/pdf"}, {"href": "https://doi.org/10.3390/bios14050215"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Biosensors", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "10.3390/bios14050215", "name": "item", "description": "10.3390/bios14050215", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/10.3390/bios14050215"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2024-04-26T00:00:00Z"}}, {"id": "10.3390/bios12121071", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:19:37Z", "type": "Journal Article", "created": "2022-11-24", "title": "One-Step Photochemical Immobilization of Aptamer on Graphene for Label-Free Detection of NT-proBNP", "description": "<?xml version='1.0' encoding='UTF-8'?><article><p>A novel photochemical technological route for one-step functionalization of a graphene surface with an azide-modified DNA aptamer for biomarkers is developed. The methodology is demonstrated for the functionalization of a DNA aptamer for an N-terminal B-type natriuretic peptide (NT-proBNP) heart failure biomarker on the surface of a graphene channel within a system based on a liquid-gated graphene field effect transistor (GFET). The limit of detection (LOD) of the aptamer-functionalized sensor is 0.01 pg/mL with short response time (75 s) for clinically relevant concentrations of the cardiac biomarker, which could be of relevance for point-of-care (POC) applications. The novel methodology could be applicable for the development of different graphene-based biosensors for fast, stable, real-time, and highly sensitive detection of disease markers.</p></article>", "keywords": ["azide modification", "field-effect transistor", "heart failure", "aptamer", "Biosensing Techniques", "02 engineering and technology", "Aptamers", " Nucleotide", "point-of-care diagnostic", "Article", "Peptide Fragments", "graphene biosensor; heart failure; field-effect transistor; point-of-care diagnostic; aptamer; azide modification; photochemistry", "Natriuretic Peptide", " Brain", "graphene biosensor", "Graphite", "0210 nano-technology", "TP248.13-248.65", "Biomarkers", "Biotechnology"]}, "links": [{"href": "http://www.mdpi.com/2079-6374/12/12/1071/pdf"}, {"href": "https://www.mdpi.com/2079-6374/12/12/1071/pdf"}, {"href": "https://doi.org/10.3390/bios12121071"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Biosensors", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "10.3390/bios12121071", "name": "item", "description": "10.3390/bios12121071", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/10.3390/bios12121071"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2022-11-23T00:00:00Z"}}, {"id": "10.3390/toxins15050326", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:19:48Z", "type": "Journal Article", "created": "2023-05-10", "title": "Label-Free Direct Detection of Cylindrospermopsin via Graphene-Enhanced Surface Plasmon Resonance Aptasensor", "description": "<?xml version='1.0' encoding='UTF-8'?><article><p>In this work, we report a novel method for the label-free detection of cyanotoxin molecules based on a direct assay utilizing a graphene-modified surface plasmon resonance (SPR) aptasensor. Molecular dynamic simulation of the aptamer\u2019s interaction with cylindrospermopsin (CYN) reveals the strongest binding sites between C18\u2013C26 pairs. To modify the SPR sensor, the wet transfer method of CVD monolayer graphene was used. For the first time, we report the use of graphene functionalized by an aptamer as a bioreceptor in conjunction with SPR for the detection of CYN. In a direct assay with an anti-CYN aptamer, we demonstrated a noticeable change in the optical signal in response to the concentrations far below the maximum tolerable level of 1 \u00b5g/L and high specificity.</p></article>", "keywords": ["Communication", "R", "aptamer", "Biosensing Techniques", "label-free biosensing", "Surface Plasmon Resonance", "Aptamers", " Nucleotide", "CVD graphene; label-free biosensing; cyanotoxins; aptamer; surface plasmon resonance", "3. Good health", "CVD graphene", "cyanotoxins", "Medicine", "Graphite", "surface plasmon resonance"]}, "links": [{"href": "https://www.mdpi.com/2072-6651/15/5/326/pdf"}, {"href": "https://doi.org/10.3390/toxins15050326"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Toxins", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "10.3390/toxins15050326", "name": "item", "description": "10.3390/toxins15050326", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/10.3390/toxins15050326"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2023-05-10T00:00:00Z"}}, {"id": "10.3390/toxins11100550", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:19:48Z", "type": "Journal Article", "created": "2019-09-20", "title": "Graphene-Based Sensing Platform for On-Chip Ochratoxin A Detection", "description": "<?xml version='1.0' encoding='UTF-8'?><article><p>In this work, we report an on-chip aptasensor for ochratoxin A (OTA) toxin detection that is based on a graphene field-effect transistor (GFET). Graphene-based devices are fabricated via large-scale technology, allowing for upscaling the sensor fabrication and lowering the device cost. The sensor assembly was performed through covalent bonding of graphene\u2019s surface with an aptamer specifically sensitive towards OTA. The results demonstrate fast (within 5 min) response to OTA exposure with a linear range of detection between 4 ng/mL and 10 pg/mL, with a detection limit of 4 pg/mL. The regeneration time constant of the sensor was found to be rather small, only 5.6 s, meaning fast sensor regeneration for multiple usages. The high reproducibility of the sensing response was demonstrated via using several recycling procedures as well as various GFETs. The applicability of the aptasensor to real samples was demonstrated for spiked red wine samples with recovery of about 105% for a 100 pM OTA concentration; the selectivity of the sensor was also confirmed via addition of another toxin, zearalenone. The developed platform opens the way for multiplex sensing of different toxins using an on-chip array of graphene sensors.</p></article>", "keywords": ["Communication", "graphene", "R", "aptamer", "Biosensing Techniques", "02 engineering and technology", "Aptamers", " Nucleotide", "Ochratoxins", "7. Clean energy", "01 natural sciences", "12. Responsible consumption", "0104 chemical sciences", "on-chip", "sensor", "Limit of Detection", "transistor", "Medicine", "Graphite", "0210 nano-technology", "ochratoxin A"]}, "links": [{"href": "https://www.mdpi.com/2072-6651/11/10/550/pdf"}, {"href": "https://doi.org/10.3390/toxins11100550"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Toxins", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "10.3390/toxins11100550", "name": "item", "description": "10.3390/toxins11100550", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/10.3390/toxins11100550"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2019-09-20T00:00:00Z"}}, {"id": "PMC11117807", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:24:58Z", "type": "Journal Article", "created": "2024-04-26", "title": "Comparative Study of Field-Effect Transistors Based on Graphene Oxide and CVD Graphene in Highly Sensitive NT-proBNP Aptasensors", "description": "<?xml version='1.0' encoding='UTF-8'?><article><p>Graphene-based materials are actively being investigated as sensing elements for the detection of different analytes. Both graphene grown by chemical vapor deposition (CVD) and graphene oxide (GO) produced by the modified Hummers\u2019 method are actively used in the development of biosensors. The production costs of CVD graphene- and GO-based sensors are similar; however, the question remains regarding the most efficient graphene-based material for the construction of point-of-care diagnostic devices. To this end, in this work, we compare CVD graphene aptasensors with the aptasensors based on reduced GO (rGO) for their capabilities in the detection of NT-proBNP, which serves as the gold standard biomarker for heart failure. Both types of aptasensors were developed using commercial gold interdigitated electrodes (IDEs) with either CVD graphene or GO formed on top as a channel of liquid-gated field-effect transistor (FET), yielding GFET and rGO-FET sensors, respectively. The functional properties of the two types of aptasensors were compared. Both demonstrate good dynamic range from 10 fg/mL to 100 pg/mL. The limit of detection for NT-proBNP in artificial saliva was 100 fg/mL and 1 pg/mL for rGO-FET- and GFET-based aptasensors, respectively. While CVD GFET demonstrates less variations in parameters, higher sensitivity was demonstrated by the rGO-FET due to its higher roughness and larger bandgap. The demonstrated low cost and scalability of technology for both types of graphene-based aptasensors may be applicable for the development of different graphene-based biosensors for rapid, stable, on-site, and highly sensitive detection of diverse biochemical markers.</p></article>", "keywords": ["Transistors", " Electronic", "graphene", "field-effect transistor", "heart failure", "aptamer", "Biosensing Techniques", "02 engineering and technology", "Aptamers", " Nucleotide", "01 natural sciences", "point-of-care diagnostic", "Article", "Peptide Fragments", "0104 chemical sciences", "Limit of Detection", "Natriuretic Peptide", " Brain", "graphene oxide", "Humans", "Graphite", "Gold", "0210 nano-technology", "Electrodes", "TP248.13-248.65", "Biomarkers", "Biotechnology"]}, "links": [{"href": "https://www.mdpi.com/2079-6374/14/5/215/pdf"}, {"href": "https://doi.org/PMC11117807"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Biosensors", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "PMC11117807", "name": "item", "description": "PMC11117807", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/PMC11117807"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2024-04-26T00:00:00Z"}}, {"id": "2104.10551", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:22:56Z", "type": "Journal Article", "created": "2021-12-15", "title": "Real-time detection of ochratoxin A in wine through insight of aptamer conformation in conjunction with graphene field-effect transistor", "description": "Mycotoxins comprise a frequent type of toxins present in food and feed. The problem of mycotoxin contamination has been recently aggravated due to the increased complexity of the farm-to-fork chains, resulting in negative effects on human and animal health and, consequently, economics. The easy-to-use, on-site, on-demand, and rapid monitoring of mycotoxins in food/feed is highly desired. In this work, we report on an advanced mycotoxin biosensor based on an array of graphene field-effect transistors integrated on a single silicon chip. A specifically designed aptamer against Ochratoxin A (OTA) was used as a recognition element, where it was covalently attached to graphene surface via pyrenebutanoic acid, succinimidyl ester (PBASE) chemistry. Namely, an electric field stimulation was used to promote more efficient \u03c0-\u03c0 stacking of PBASE to graphene. The specific G-rich aptamer strand suggest its \u03c0-\u03c0 stacking on graphene in free-standing regime and reconfiguration in G-quadruplex during binding an OTA molecule. This realistic behavior of the aptamer is sensitive to the ionic strength of the analyte solution, demonstrating a 10-fold increase in sensitivity at low ionic strengths. The graphene-aptamer sensors reported here demonstrate fast assay with the lowest detection limit of 1.4 pM for OTA within a response time as low as 10 s, which is more than 30 times faster compared to any other reported aptamer-based methods for mycotoxin detection. The sensors hold comparable performance when operated in real-time within a complex matrix of wine without additional time-consuming pre-treatment.", "keywords": ["Condensed Matter - Materials Science", "Condensed Matter - Mesoscale and Nanoscale Physics", "Materials Science (cond-mat.mtrl-sci)", "FOS: Physical sciences", "Wine", "Biosensing Techniques", "02 engineering and technology", "Aptamers", " Nucleotide", "Ochratoxins", "01 natural sciences", "0104 chemical sciences", "Limit of Detection", "Mesoscale and Nanoscale Physics (cond-mat.mes-hall)", "Animals", "Humans", "Graphite", "0210 nano-technology"]}, "links": [{"href": "https://doi.org/2104.10551"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Biosensors%20and%20Bioelectronics", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "2104.10551", "name": "item", "description": "2104.10551", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/2104.10551"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2022-03-01T00:00:00Z"}}, {"id": "2311.04674", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:23:01Z", "type": "Journal Article", "created": "2024-04-09", "title": "Direct electrochemical reduction of graphene oxide thin film for aptamer-based selective and highly sensitive detection of matrix metalloproteinase 2", "description": "Simple and low-cost biosensing solutions are suitable for point-of-care applications aiming to overcome the gap between scientific concepts and technological production. To compete with sensitivity and selectivity of golden standards, such as liquid chromatography, the functionalization of biosensors is continuously optimized to enhance the signal and improve their performance, often leading to complex chemical assay development. In this research, the efforts are made on optimizing the methodology for electrochemical reduction of graphene oxide to produce thin film-modified gold electrodes. Under the employed specific conditions, 20 cycles of cyclic voltammetry (CV) are shown to be optimal for superior electrical activation of graphene oxide into electrochemically reduced graphene oxide (ERGO). This platform is further used to develop a matrix metalloproteinase 2 (MMP-2) biosensor, where specific anti-MMP2 aptamers are utilized as a biorecognition element. MMP-2 is a protein which is typically overexpressed in tumor tissues, with important roles in tumor invasion, metastasis as well as in tumor angiogenesis. Based on impedimetric measurements, we were able to detect as low as 3.32 pg/mL of MMP-2 in PBS with a dynamic range of 10 pg/mL - 10 ng/mL. Besides high specificity, ERGO-based aptasensor showed a potential of reuse due to demonstrated successful signal restoration after experimental detection of MMP-2.", "keywords": ["Physics - Instrumentation and Detectors", "FOS: Physical sciences", "Biomolecules (q-bio.BM)", "Physics - Applied Physics", "Electrochemical Techniques", "Biosensing Techniques", "02 engineering and technology", "Applied Physics (physics.app-ph)", "Instrumentation and Detectors (physics.ins-det)", "Aptamers", " Nucleotide", "01 natural sciences", "0104 chemical sciences", "03 medical and health sciences", "0302 clinical medicine", "Quantitative Biology - Biomolecules", "Limit of Detection", "FOS: Biological sciences", "Matrix Metalloproteinase 2", "Humans", "Graphite", "Gold", "0210 nano-technology", "Oxidation-Reduction", "Electrodes"]}, "links": [{"href": "https://doi.org/2311.04674"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Talanta", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "2311.04674", "name": "item", "description": "2311.04674", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/2311.04674"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2024-07-01T00:00:00Z"}}, {"id": "2974072884", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:23:12Z", "type": "Journal Article", "created": "2019-09-20", "title": "Graphene-Based Sensing Platform for On-Chip Ochratoxin A Detection", "description": "<?xml version='1.0' encoding='UTF-8'?><article><p>In this work, we report an on-chip aptasensor for ochratoxin A (OTA) toxin detection that is based on a graphene field-effect transistor (GFET). Graphene-based devices are fabricated via large-scale technology, allowing for upscaling the sensor fabrication and lowering the device cost. The sensor assembly was performed through covalent bonding of graphene\u2019s surface with an aptamer specifically sensitive towards OTA. The results demonstrate fast (within 5 min) response to OTA exposure with a linear range of detection between 4 ng/mL and 10 pg/mL, with a detection limit of 4 pg/mL. The regeneration time constant of the sensor was found to be rather small, only 5.6 s, meaning fast sensor regeneration for multiple usages. The high reproducibility of the sensing response was demonstrated via using several recycling procedures as well as various GFETs. The applicability of the aptasensor to real samples was demonstrated for spiked red wine samples with recovery of about 105% for a 100 pM OTA concentration; the selectivity of the sensor was also confirmed via addition of another toxin, zearalenone. The developed platform opens the way for multiplex sensing of different toxins using an on-chip array of graphene sensors.</p></article>", "keywords": ["Communication", "graphene", "R", "aptamer", "Biosensing Techniques", "02 engineering and technology", "Aptamers", " Nucleotide", "Ochratoxins", "01 natural sciences", "7. Clean energy", "0104 chemical sciences", "12. Responsible consumption", "on-chip", "sensor", "Limit of Detection", "transistor", "Medicine", "Graphite", "0210 nano-technology", "ochratoxin A"]}, "links": [{"href": "https://www.mdpi.com/2072-6651/11/10/550/pdf"}, {"href": "https://doi.org/2974072884"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Toxins", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "2974072884", "name": "item", "description": "2974072884", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/2974072884"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2019-09-20T00:00:00Z"}}, {"id": "PMC10220545", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:24:57Z", "type": "Journal Article", "created": "2023-05-10", "title": "Label-Free Direct Detection of Cylindrospermopsin via Graphene-Enhanced Surface Plasmon Resonance Aptasensor", "description": "<?xml version='1.0' encoding='UTF-8'?><article><p>In this work, we report a novel method for the label-free detection of cyanotoxin molecules based on a direct assay utilizing a graphene-modified surface plasmon resonance (SPR) aptasensor. Molecular dynamic simulation of the aptamer\u2019s interaction with cylindrospermopsin (CYN) reveals the strongest binding sites between C18\u2013C26 pairs. To modify the SPR sensor, the wet transfer method of CVD monolayer graphene was used. For the first time, we report the use of graphene functionalized by an aptamer as a bioreceptor in conjunction with SPR for the detection of CYN. In a direct assay with an anti-CYN aptamer, we demonstrated a noticeable change in the optical signal in response to the concentrations far below the maximum tolerable level of 1 \u00b5g/L and high specificity.</p></article>", "keywords": ["CVD graphene", "cyanotoxins", "Communication", "R", "aptamer", "Medicine", "Graphite", "Biosensing Techniques", "label-free biosensing", "Surface Plasmon Resonance", "Aptamers", " Nucleotide", "surface plasmon resonance", "3. Good health"]}, "links": [{"href": "https://www.mdpi.com/2072-6651/15/5/326/pdf"}, {"href": "https://doi.org/PMC10220545"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Toxins", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "PMC10220545", "name": "item", "description": "PMC10220545", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/PMC10220545"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2023-05-10T00:00:00Z"}}, {"id": "PMC6832591", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:25:01Z", "type": "Journal Article", "created": "2019-09-20", "title": "Graphene-Based Sensing Platform for On-Chip Ochratoxin A Detection", "description": "<?xml version='1.0' encoding='UTF-8'?><article><p>In this work, we report an on-chip aptasensor for ochratoxin A (OTA) toxin detection that is based on a graphene field-effect transistor (GFET). Graphene-based devices are fabricated via large-scale technology, allowing for upscaling the sensor fabrication and lowering the device cost. The sensor assembly was performed through covalent bonding of graphene\u2019s surface with an aptamer specifically sensitive towards OTA. The results demonstrate fast (within 5 min) response to OTA exposure with a linear range of detection between 4 ng/mL and 10 pg/mL, with a detection limit of 4 pg/mL. The regeneration time constant of the sensor was found to be rather small, only 5.6 s, meaning fast sensor regeneration for multiple usages. The high reproducibility of the sensing response was demonstrated via using several recycling procedures as well as various GFETs. The applicability of the aptasensor to real samples was demonstrated for spiked red wine samples with recovery of about 105% for a 100 pM OTA concentration; the selectivity of the sensor was also confirmed via addition of another toxin, zearalenone. The developed platform opens the way for multiplex sensing of different toxins using an on-chip array of graphene sensors.</p></article>", "keywords": ["Communication", "graphene", "R", "aptamer", "Biosensing Techniques", "02 engineering and technology", "Aptamers", " Nucleotide", "Ochratoxins", "01 natural sciences", "7. Clean energy", "0104 chemical sciences", "12. Responsible consumption", "on-chip", "sensor", "Limit of Detection", "transistor", "Medicine", "Graphite", "0210 nano-technology", "ochratoxin A"]}, "links": [{"href": "https://www.mdpi.com/2072-6651/11/10/550/pdf"}, {"href": "https://doi.org/PMC6832591"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Toxins", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "PMC6832591", "name": "item", "description": "PMC6832591", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/PMC6832591"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2019-09-20T00:00:00Z"}}, {"id": "PMC9775241", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:25:06Z", "type": "Journal Article", "created": "2022-11-24", "title": "One-Step Photochemical Immobilization of Aptamer on Graphene for Label-Free Detection of NT-proBNP", "description": "<?xml version='1.0' encoding='UTF-8'?><article><p>A novel photochemical technological route for one-step functionalization of a graphene surface with an azide-modified DNA aptamer for biomarkers is developed. The methodology is demonstrated for the functionalization of a DNA aptamer for an N-terminal B-type natriuretic peptide (NT-proBNP) heart failure biomarker on the surface of a graphene channel within a system based on a liquid-gated graphene field effect transistor (GFET). The limit of detection (LOD) of the aptamer-functionalized sensor is 0.01 pg/mL with short response time (75 s) for clinically relevant concentrations of the cardiac biomarker, which could be of relevance for point-of-care (POC) applications. The novel methodology could be applicable for the development of different graphene-based biosensors for fast, stable, real-time, and highly sensitive detection of disease markers.</p></article>", "keywords": ["azide modification", "field-effect transistor", "heart failure", "aptamer", "Biosensing Techniques", "02 engineering and technology", "Aptamers", " Nucleotide", "point-of-care diagnostic", "Article", "Peptide Fragments", "graphene biosensor; heart failure; field-effect transistor; point-of-care diagnostic; aptamer; azide modification; photochemistry", "Natriuretic Peptide", " Brain", "graphene biosensor", "Graphite", "0210 nano-technology", "TP248.13-248.65", "Biomarkers", "Biotechnology"]}, "links": [{"href": "http://www.mdpi.com/2079-6374/12/12/1071/pdf"}, {"href": "https://www.mdpi.com/2079-6374/12/12/1071/pdf"}, {"href": "https://doi.org/PMC9775241"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Biosensors", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "PMC9775241", "name": "item", "description": "PMC9775241", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/PMC9775241"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2022-11-23T00:00:00Z"}}, {"id": "eee4346853957c59c220684ad5212d19", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:26:49Z", "type": "Journal Article", "created": "2021-12-16", "title": "Real-time detection of ochratoxin A in wine through insight of aptamer conformation in conjunction with graphene field-effect transistor", "description": "Mycotoxins comprise a frequent type of toxins present in food and feed. The problem of mycotoxin contamination has been recently aggravated due to the increased complexity of the farm-to-fork chains, resulting in negative effects on human and animal health and, consequently, economics. The easy-to-use, on-site, on-demand, and rapid monitoring of mycotoxins in food/feed is highly desired. In this work, we report on an advanced mycotoxin biosensor based on an array of graphene field-effect transistors integrated on a single silicon chip. A specifically designed aptamer against Ochratoxin A (OTA) was used as a recognition element, where it was covalently attached to graphene surface via pyrenebutanoic acid, succinimidyl ester (PBASE) chemistry. Namely, an electric field stimulation was used to promote more efficient \u03c0-\u03c0 stacking of PBASE to graphene. The specific G-rich aptamer strand suggest its \u03c0-\u03c0 stacking on graphene in free-standing regime and reconfiguration in G-quadruplex during binding an OTA molecule. This realistic behavior of the aptamer is sensitive to the ionic strength of the analyte solution, demonstrating a 10-fold increase in sensitivity at low ionic strengths. The graphene-aptamer sensors reported here demonstrate fast assay with the lowest detection limit of 1.4 pM for OTA within a response time as low as 10 s, which is more than 30 times faster compared to any other reported aptamer-based methods for mycotoxin detection. The sensors hold comparable performance when operated in real-time within a complex matrix of wine without additional time-consuming pre-treatment.", "keywords": ["Condensed Matter - Materials Science", "Condensed Matter - Mesoscale and Nanoscale Physics", "Materials Science (cond-mat.mtrl-sci)", "FOS: Physical sciences", "Wine", "Biosensing Techniques", "02 engineering and technology", "Aptamers", " Nucleotide", "Ochratoxins", "01 natural sciences", "3. Good health", "0104 chemical sciences", "Limit of Detection", "Mesoscale and Nanoscale Physics (cond-mat.mes-hall)", "Animals", "Humans", "Graphite", "0210 nano-technology"]}, "links": [{"href": "https://doi.org/http://arxiv.org/abs/2104.10551"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Biosensors%20and%20Bioelectronics", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "eee4346853957c59c220684ad5212d19", "name": "item", "description": "eee4346853957c59c220684ad5212d19", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/eee4346853957c59c220684ad5212d19"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2022-03-01T00:00:00Z"}}], "links": [{"rel": "self", "type": "application/geo+json", "title": "This document as GeoJSON", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=Aptamers&f=json", "hreflang": "en-US"}, {"rel": "alternate", "type": "text/html", "title": "This document as HTML", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=Aptamers&f=html", "hreflang": "en-US"}, {"rel": "collection", "type": "application/json", "title": "Collection URL", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main", "hreflang": "en-US"}, {"type": "application/geo+json", "rel": "first", "title": "items (first)", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=Aptamers&", "hreflang": "en-US"}, {"rel": "last", "type": "application/geo+json", "title": "items (last)", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=Aptamers&offset=13", "hreflang": "en-US"}], "numberMatched": 13, "numberReturned": 13, "distributedFeatures": [], "timeStamp": "2026-11-24T13:03:44.888048Z"}