{"type": "FeatureCollection", "features": [{"id": "10.1016/j.cej.2020.125389", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:15:50Z", "type": "Journal Article", "created": "2020-05-08", "title": "Anomalies detected during hydrodynamic cavitation when using salicylic acid dosimetry to measure radical production", "description": "Abstract   Cavitation used to be associated with negative outcomes in hydraulic turbomachinery but nowadays it is often used for water cleaning, microorganism\u2019s destruction and degradation of organic compounds. This study investigated the amount of  OH formed during hydrodynamic cavitation using salicylic acid dosimetry. The radical\u2019s amount was evaluated by quantifying the concentration of 2,3-dihydroxybenzoic acid, catechol and 2,5-dihydroxybenzoic acid. Two concentrations of the dosimeter in tap water were investigated, 50 and 300\u00a0mg L\u22121 (pH approx. 2.5). After 90\u00a0min of cavitation using a Venturi constriction a sum of the three products was determined at 0.97\u00a0\u00b5g\u00a0mL\u22121 and 1.81\u00a0\u00b5g\u00a0mL\u22121, respectively. However, during the investigation the anomalies were detected in the cavitation development when higher concentration of salicylic acid was used \u2013 cavitation appeared more gentle, with less intense collapses, unrelated to the one in pure water. Detailed observations of cavitation and additional bubble dynamics simulations revealed that the decreased surface tension of the acidified salicylic acid solution is the most influential physical characteristic. Further experiments on nucleation and coalescence showed that high concentration of salicylic acid also leads to longer stability of the bubbles and prevents their coalescence due to short-range repulsive forces (steric hindrance), which results in less violent bubble collapse. We also discuss the importance of an appropriate amount of the dosimeter for correct evaluation of  OH production in a given cavitation device (50\u00a0mg L\u22121 for the present one). This is essential for further cavitation exploitation studies to avoid false interpretation of the gathered results.", "keywords": ["coalescence", "dozimetrija salicilne kisline", "koalescenca", "nukleacija", "nucleation", "anomalije", "04 agricultural and veterinary sciences", "info:eu-repo/classification/udc/532.528(045)", "6. Clean water", "kavitacija", "salicylic acid dosimetry", "0404 agricultural biotechnology", "cavitation", "fizikalne lastnosti", "physical characteristics", "anomalies", "0405 other agricultural sciences"]}, "links": [{"href": "https://doi.org/10.1016/j.cej.2020.125389"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Chemical%20Engineering%20Journal", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "10.1016/j.cej.2020.125389", "name": "item", "description": "10.1016/j.cej.2020.125389", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/10.1016/j.cej.2020.125389"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2020-09-01T00:00:00Z"}}, {"id": "10.1117/12.2624440", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:18:21Z", "type": "Journal Article", "created": "2022-05-19", "title": "Perfluorinated polymer fibre Bragg grating sensors for distributed low-dose clinical X-ray measurements", "description": "Optical fibres have played an important role in the advancement of real-time dosimetry in clinical applications in recent years. Significant work has been done to increase precision and accuracy in detecting radiation doses during treatment, to avoid the negative effect that can ensue from irradiating healthy tissue around the tumour. The drive to develop distributed measurement in optical fibres has been limited to the slow scanning speed systems from optical time domain reflectometry (OTDR), however for radiotherapy dosimetry, with often short radiation pulse durations, fibre Bragg grating (FBG) interrogation is a better alternative because of the fast-scanning speed. The work presented here includes the preliminary results in the characterisation of CYTOP FBGs on exposure to X-ray radiation emitted from a clinical linear accelerator (linac) machine. A blue shifted linear response of the Bragg wavelength with sensitivity of 6.655 pm/Gy, 6.519 pm/Gy and 7.153 pm/Gy at the three main peaks (1522 nm, 1542 and 1561 nm), was recorded for a 9 Gy of radiation at a dose rate of 1.758 Gy/min with an amplitude fluctuation within the duration of radiation. The response demonstrates the potential for its use in low dose radiation dosimetry, providing for quasi-distributed sensing in radiotherapy.", "keywords": ["0211 other engineering and technologies", "fibre optics dosimetry", "02 engineering and technology", "Electrical Engineering - Electronic Engineering - Information Engineering", "X-ray", "Fibre Bragg grating", "Optical fibres", "Radiation Monitoring", "Dosimetry", "fibre Bragg grating sensors", "0202 electrical engineering", " electronic engineering", " information engineering", "fibre optics sensors", "Engineering and Technology", "CYTOP", "low-dose clinical X-ray measurements"]}, "links": [{"href": "https://doi.org/10.1117/12.2624440"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Micro-Structured%20and%20Specialty%20Optical%20Fibres%20VII", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "10.1117/12.2624440", "name": "item", "description": "10.1117/12.2624440", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/10.1117/12.2624440"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2022-05-19T00:00:00Z"}}, {"id": "10.3390/s23010039", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:19:47Z", "type": "Journal Article", "created": "2022-12-21", "title": "Online Gamma Radiation Monitoring Using Few-Mode Polymer CYTOP Fiber Bragg Gratings", "description": "<p>We investigated the gamma radiation response of fiber Bragg gratings (FBGs) inscribed in a few-mode polymer optical fiber. The fiber had a graded-index CYTOP core of 20 \uffc2\uffb5m and XYLEX overclad of 250 \uffc2\uffb5m in diameter. Four FBGs were exposed to gamma radiation during four irradiation sessions at a 5.3 kGy/h dose rate. The FBGs showed a linear Bragg wavelength shift with the received dose with a mean sensitivity of \uffe2\uff88\uff923.95 pm/kGy at 43 \uffc2\uffb0C. The increased temperature provides a rise in the sensitivity: it reached \uffe2\uff88\uff9210.6 pm/kGy at 58 \uffc2\uffb0C. After irradiation, the FBGs showed partial recovery, which increased with the received dose. Furthermore, the FBG\uffe2\uff80\uff99s reflection power decreased with the dose. This attenuation is mainly due to insertion losses caused by the radiation induced attenuation in the CYTOP fiber. Linear response to the received dose makes CYTOP FBGs attractive for gamma radiation dosimetry. However, temperature dependence of the sensitivity should be compensated in practical applications.</p>", "keywords": ["Chemical technology", "gamma radiation", "polymer perfluorinated fiber", "TP1-1185", "02 engineering and technology", "Electrical Engineering - Electronic Engineering - Information Engineering", "01 natural sciences", "Article", "polymer optical fiber", "0103 physical sciences", "0202 electrical engineering", " electronic engineering", " information engineering", "Engineering and Technology", "fiber Bragg gratings", "polymer optical fiber; gamma radiation dosimetry; fiber Bragg gratings; gamma radiation; CYTOP; polymer perfluorinated fiber", "gamma radiation dosimetry", "CYTOP"]}, "links": [{"href": "http://www.mdpi.com/1424-8220/23/1/39/pdf"}, {"href": "https://www.mdpi.com/1424-8220/23/1/39/pdf"}, {"href": "https://doi.org/10.3390/s23010039"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Sensors", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "10.3390/s23010039", "name": "item", "description": "10.3390/s23010039", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/10.3390/s23010039"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2022-12-21T00:00:00Z"}}], "links": [{"rel": "self", "type": "application/geo+json", "title": "This document as GeoJSON", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=Dosimetry&f=json", "hreflang": "en-US"}, {"rel": "alternate", "type": "text/html", "title": "This document as HTML", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=Dosimetry&f=html", "hreflang": "en-US"}, {"rel": "collection", "type": "application/json", "title": "Collection URL", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main", "hreflang": "en-US"}, {"type": "application/geo+json", "rel": "first", "title": "items (first)", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=Dosimetry&", "hreflang": "en-US"}, {"rel": "last", "type": "application/geo+json", "title": "items (last)", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=Dosimetry&offset=3", "hreflang": "en-US"}], "numberMatched": 3, "numberReturned": 3, "distributedFeatures": [], "timeStamp": "2026-11-25T06:12:05.245968Z"}