{"type": "FeatureCollection", "features": [{"id": "2311.04674", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:23:01Z", "type": "Journal Article", "created": "2024-04-09", "title": "Direct electrochemical reduction of graphene oxide thin film for aptamer-based selective and highly sensitive detection of matrix metalloproteinase 2", "description": "Simple and low-cost biosensing solutions are suitable for point-of-care applications aiming to overcome the gap between scientific concepts and technological production. To compete with sensitivity and selectivity of golden standards, such as liquid chromatography, the functionalization of biosensors is continuously optimized to enhance the signal and improve their performance, often leading to complex chemical assay development. In this research, the efforts are made on optimizing the methodology for electrochemical reduction of graphene oxide to produce thin film-modified gold electrodes. Under the employed specific conditions, 20 cycles of cyclic voltammetry (CV) are shown to be optimal for superior electrical activation of graphene oxide into electrochemically reduced graphene oxide (ERGO). This platform is further used to develop a matrix metalloproteinase 2 (MMP-2) biosensor, where specific anti-MMP2 aptamers are utilized as a biorecognition element. MMP-2 is a protein which is typically overexpressed in tumor tissues, with important roles in tumor invasion, metastasis as well as in tumor angiogenesis. Based on impedimetric measurements, we were able to detect as low as 3.32 pg/mL of MMP-2 in PBS with a dynamic range of 10 pg/mL - 10 ng/mL. Besides high specificity, ERGO-based aptasensor showed a potential of reuse due to demonstrated successful signal restoration after experimental detection of MMP-2.", "keywords": ["Physics - Instrumentation and Detectors", "FOS: Physical sciences", "Biomolecules (q-bio.BM)", "Physics - Applied Physics", "Electrochemical Techniques", "Biosensing Techniques", "02 engineering and technology", "Applied Physics (physics.app-ph)", "Instrumentation and Detectors (physics.ins-det)", "Aptamers", " Nucleotide", "01 natural sciences", "0104 chemical sciences", "03 medical and health sciences", "0302 clinical medicine", "Quantitative Biology - Biomolecules", "Limit of Detection", "FOS: Biological sciences", "Matrix Metalloproteinase 2", "Humans", "Graphite", "Gold", "0210 nano-technology", "Oxidation-Reduction", "Electrodes"]}, "links": [{"href": "https://doi.org/2311.04674"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Talanta", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "2311.04674", "name": "item", "description": "2311.04674", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/2311.04674"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2024-07-01T00:00:00Z"}}, {"id": "2307.16692", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:23:01Z", "type": "Journal Article", "created": "2023-11-10", "title": "Femtomolar detection of the heart failure biomarker NT-proBNP in artificial saliva using an immersible liquid-gated aptasensor with reduced graphene oxide", "description": "Measuring NT-proBNP biomarker is recommended for preliminary diagnostics of the heart failure. Recent studies suggest a possibility of early screening of biomarkers in saliva for non-invasive identification of cardiac diseases at the point-of-care. However, NT-proBNP concentrations in saliva can be thousand time lower than in blood plasma, going down to pg/mL level. To reach this level, we developed a label-free aptasensor based on a liquid-gated field effect transistor using a film of reduced graphene oxide monolayer (rGO-FET) with immobilized NT-proBNP specific aptamer. We found that, depending on ionic strength of tested solutions, there were different levels of correlation in responses of electrical parameters of the rGO-FET aptasensor, namely, the Dirac point shift and transconductance change. The correlation in response to NT-proBNP was high for 1.6 mM phosphate-buffered saline (PBS) and zero for 16 mM PBS in a wide range of analyte concentrations, varied from 1 fg/mL to 10 ng/mL. The effects of transconductance and Dirac point shift in PBS solutions of different concentrations are discussed. The biosensor exhibited a high sensitivity for both transconductance (2 uS/decade) and Dirac point shift (2.3 mV/decade) in diluted PBS with the linear range from 10 fg/mL to 1 pg/mL. The aptasensor performance has been also demonstrated in undiluted artificial saliva with the achieved limit of detection down to 41 fg/mL (~4.6 fM).", "keywords": ["Condensed Matter - Materials Science", "Physics - Instrumentation and Detectors", "Condensed Matter - Mesoscale and Nanoscale Physics", "Materials Science (cond-mat.mtrl-sci)", "FOS: Physical sciences", "Biomolecules (q-bio.BM)", "Physics - Applied Physics", "Applied Physics (physics.app-ph)", "Instrumentation and Detectors (physics.ins-det)", "02 engineering and technology", "01 natural sciences", "0104 chemical sciences", "Quantitative Biology - Biomolecules", "FOS: Biological sciences", "Mesoscale and Nanoscale Physics (cond-mat.mes-hall)", "0210 nano-technology"]}, "links": [{"href": "https://doi.org/2307.16692"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Microchemical%20Journal", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "2307.16692", "name": "item", "description": "2307.16692", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/2307.16692"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2024-01-01T00:00:00Z"}}, {"id": "2410.1244", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:23:02Z", "type": "Report", "title": "Surface plasmon resonance sensor based on a novel prism for the detection of a broad range of polymers", "description": "Open AccessMicroplastics are pervasive pollutants that pose threats to the environment and human health. Detecting them reliably represents a crucial step toward finding solutions. While traditional techniques like vibrational and mass spectroscopies are time-consuming and have limitations in analysing polymers with pigment additives, surface plasmon resonance (SPR) shows promise due to its high sensitivity and rapid detection capabilities.However, existing SPR methods rely on one output variable and fail to determine various microplastic parameters simultaneously. To address this uncertainty between size and polymer type, we propose a prism design that enables SPR resonance in a refractive index range of 1.402-1.56 RIU (Refractive Index Units) for polymer detection. Experimental verification of the prism's dynamic range using refractive index oils presented an agreement of 98.47% with theoretical analysis. Furthermore, we acquired SPR curves from ten different polymer types, including Nitrile, Viton and Tyre rubber. These results demonstrate SPR's potential to identify polymers and its ability to detect even pigmented materials, often challenging for other techniques. The imaging capabilities of the novel prism are presented, indicating its potential for future imaging of microplastics. Our approach holds promise for advancing microplastics analysis by enabling comprehensive assessment of particle parameters, such as polymer type, size, quantity and shape, and expanding the range of detectable polymer types.", "keywords": ["Physics - Instrumentation and Detectors", "FOS: Physical sciences", "Instrumentation and Detectors (physics.ins-det)"], "contacts": [{"organization": "Andrade, Natalia A. Gutierrez, Nie, Yunfeng, Meulebroeck, Wendy, Ottevaere, Heidi,", "roles": ["creator"]}]}, "links": [{"href": "https://doi.org/2410.1244"}, {"rel": "self", "type": "application/geo+json", "title": "2410.1244", "name": "item", "description": "2410.1244", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/2410.1244"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2024-01-01T00:00:00Z"}}], "links": [{"rel": "self", "type": "application/geo+json", "title": "This document as GeoJSON", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=Instrumentation+and+Detectors+%28physics.ins-det%29&f=json", "hreflang": "en-US"}, {"rel": "alternate", "type": "text/html", "title": "This document as HTML", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=Instrumentation+and+Detectors+%28physics.ins-det%29&f=html", "hreflang": "en-US"}, {"rel": "collection", "type": "application/json", "title": "Collection URL", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main", "hreflang": "en-US"}, {"type": "application/geo+json", "rel": "first", "title": "items (first)", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=Instrumentation+and+Detectors+%28physics.ins-det%29&", "hreflang": "en-US"}, {"rel": "last", "type": "application/geo+json", "title": "items (last)", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=Instrumentation+and+Detectors+%28physics.ins-det%29&offset=3", "hreflang": "en-US"}], "numberMatched": 3, "numberReturned": 3, "distributedFeatures": [], "timeStamp": "2026-11-25T11:08:37.604029Z"}