{"type": "FeatureCollection", "features": [{"id": "10.1029/2019GL083025", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:17:12Z", "type": "Journal Article", "created": "2019-06-06", "title": "Peatland Volume Mapping over Resistive Substrates with Airborne Electromagnetic Technology", "description": "Abstract<p>Despite the importance of peatlands as carbon reservoirs, a reliable methodology for the detection of peat volumes at regional scale is still missing. In this study we explore for the first time the use of airborne electromagnetic (AEM) to detect and quantify peat thickness and extension of two bogs located in Norway, where peat lays over resistive bedrock. Our results show that when calibrated using a small amount of field measurements, AEM can successfully detect peat volume even in less ideal conditions, that is, relatively resistive peat over resistive substrata. We expect the performance of AEM to increase significantly in presence of a conductive substratum without need of calibration with field data. The organic carbon content retrieved from field surveys and laboratory analyses combined with the 3\uffe2\uff80\uff90D model of the peat extracted from AEM allowed us to quantify the total organic carbon of the selected bogs, hence assessing the carbon pool.</p>", "keywords": ["13. Climate action", "CRESCENDO", " Marie Sk\u0142odowska-Curie action", " peatlands", " peat samples", " peat thickness", " Norway", " bogs", " Airborne Electromagnetics", " SkyTEM", " organic carbon content", " carbon pool", "Airborne electromagnetic; organic carbon; peat thickness; peatlands", " Marie Curie fellowship", "15. Life on land", "01 natural sciences", "0105 earth and related environmental sciences"]}, "links": [{"href": "https://cris.unibo.it/bitstream/11585/717338/1/Silvestri_et_al-2019-Geophysical_Research_Letters.pdf"}, {"href": "https://agupubs.onlinelibrary.wiley.com/doi/pdf/10.1029/2019GL083025"}, {"href": "https://doi.org/10.1029/2019GL083025"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Geophysical%20Research%20Letters", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "10.1029/2019GL083025", "name": "item", "description": "10.1029/2019GL083025", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/10.1029/2019GL083025"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2019-06-24T00:00:00Z"}}, {"id": "10.3390/s18072250", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:19:46Z", "type": "Journal Article", "created": "2018-07-12", "title": "Biosensing System for Concentration Quantification of Magnetically Labeled E. coli in Water Samples", "description": "<?xml version='1.0' encoding='UTF-8'?><article><p>Bacterial contamination of water sources (e.g., lakes, rivers and springs) from waterborne bacteria is a crucial water safety issue and its prevention is of the utmost significance since it threatens the health and well-being of wildlife, livestock, and human populations and can lead to serious illness and even death. Rapid and multiplexed measurement of such waterborne pathogens is vital and the challenge is to instantly detect in these liquid samples different types of pathogens with high sensitivity and specificity. In this work, we propose a biosensing system in which the bacteria are labelled with streptavidin coated magnetic markers (MPs\u2014magnetic particles) forming compounds (MLBs\u2014magnetically labelled bacteria). Video microscopy in combination with a particle tracking software are used for their detection and quantification. When the liquid containing the MLBs is introduced into the developed, microfluidic platform, the MLBs are accelerated towards the outlet by means of a magnetic field gradient generated by integrated microconductors, which are sequentially switched ON and OFF by a microcontroller. The velocities of the MLBs and that of reference MPs, suspended in the same liquid in a parallel reference microfluidic channel, are calculated and compared in real time by a digital camera mounted on a conventional optical microscope in combination with a particle trajectory tracking software. The MLBs will be slower than the reference MPs due to the enhanced Stokes\u2019 drag force exerted on them, resulting from their greater volume and altered hydrodynamic shape. The results of the investigation showed that the parameters obtained from this method emerged as reliable predictors for E. coli concentrations.</p></article>", "keywords": ["0301 basic medicine", "0303 health sciences", "magnetophoresis", "magnetic microparticles", "Chemical technology", "magnetic labeling", "Microfluidics", "TP1-1185", "Biosensing Techniques", "Article", "6. Clean water", "particle tracking", "Magnetics", "03 medical and health sciences", "bacteria quantification", "13. Climate action", "Escherichia coli", "biosensing", "Water Microbiology"]}, "links": [{"href": "http://www.mdpi.com/1424-8220/18/7/2250/pdf"}, {"href": "https://doi.org/10.3390/s18072250"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Sensors", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "10.3390/s18072250", "name": "item", "description": "10.3390/s18072250", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/10.3390/s18072250"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2018-07-12T00:00:00Z"}}, {"id": "10.5281/zenodo.3238632", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:21:19Z", "type": "Report", "title": "CRESCENDO_Brottum_Aug-Sept-2017", "description": "Open AccessThis file includes several work sheets with the data used for the article 'Peatland Volume Mapping over Resistive Substrates with Airborne Electromagnetic Technology', Silvestri et al. 2019, GRL, DOI; 10.1029/2019GL083025. Field survey performed near Brottum, Norway, on two bogs. Field survey measurements geo-located with DGPS Trimble GeoXH 3.5G: coordinates of the points available in the data set. Peat thickness was retrieved with a peat auger. Peat samples collected at three different depth intervals: between 50 cm and 100 cm; between 250 cm and 300 cm; between 800 cm and 850 cm; all peat samples are 50 cm long but there are five with length shorter than 50 cm (see comments in the table). Laboratory analyses performed to retrieve bulk density and LOI (two replicates for each sample). The file also includes the elevations of the peat bottom calculated running the ANN for 50 times and computing the mean on the inverted SkyTEM data. The leave-one-out statistics results are also included.", "keywords": ["CRESCENDO", " Marie Sk\u0142odowska-Curie action", " peatlands", " peat samples", " peat thickness", " Norway", " bogs", " Airborne Electromagnetics", " SkyTEM", " organic carbon content", " carbon pool", "15. Life on land"], "contacts": [{"organization": "Silvestri, Sonia, Christensen, Craig W., Lysdahl, Asgeir O. K., Ansch\u00fctz, Helgard, Pfaffhuber, Andreas A., Viezzoli, Andrea,", "roles": ["creator"]}]}, "links": [{"href": "https://doi.org/10.5281/zenodo.3238632"}, {"rel": "self", "type": "application/geo+json", "title": "10.5281/zenodo.3238632", "name": "item", "description": "10.5281/zenodo.3238632", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/10.5281/zenodo.3238632"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2019-06-04T00:00:00Z"}}, {"id": "10.5281/zenodo.3572061", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:21:21Z", "type": "Dataset", "title": "Field-lab data and analyses results West Kalimantan, Indonesia", "description": "Open AccessField data included in this compressed folder were collected over an area of approximately 23,500 hectares in West Kalimantan, Indonesia. The folder includes Excel and txt files with the following contents: field measurements of the peat thickness at 63 coring sites, laboratory analyses results of the samples collected in the field, field and lab measurements of electrical conductivity. Moreover, there is a file containing all the measurements of peat thickness and soil elevation extracted from the figures contained in previous studies. Finally, the folder also includes the results obtained from the inversion of the Airborne Electromagntic (AEM) data collected with the SkyTEM instrument over the study site, and specifically the resistivity of the soil layers obtained from the inversion and the peat thickness corresponding to the 45 Ohmm threshold. The folder also includes the Python codes used for the statistical analyses explained in the paper.", "keywords": ["13. Climate action", "15. Life on land", "Organic carbon content", " Airborne Electromagnetics", " CRESCENDO", " Marie Sk\u0142odowska-Curie action", " peatlands", " peat thickness", " peat volume", " Indonesia", " SkyTEM", " carbon pool"], "contacts": [{"organization": "Sonia, Silvestri, Knight Rosemary, Viezzoli Andrea, Richardson Curtis, Anshari Gusti, Dewar Noah, Flanagan Neal, Comas Xavier,", "roles": ["creator"]}]}, "links": [{"href": "https://doi.org/10.5281/zenodo.3572061"}, {"rel": "self", "type": "application/geo+json", "title": "10.5281/zenodo.3572061", "name": "item", "description": "10.5281/zenodo.3572061", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/10.5281/zenodo.3572061"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2019-12-12T00:00:00Z"}}, {"id": "2867552234", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:23:08Z", "type": "Journal Article", "created": "2018-07-12", "title": "Biosensing System for Concentration Quantification of Magnetically Labeled E. coli in Water Samples", "description": "<?xml version='1.0' encoding='UTF-8'?><article><p>Bacterial contamination of water sources (e.g., lakes, rivers and springs) from waterborne bacteria is a crucial water safety issue and its prevention is of the utmost significance since it threatens the health and well-being of wildlife, livestock, and human populations and can lead to serious illness and even death. Rapid and multiplexed measurement of such waterborne pathogens is vital and the challenge is to instantly detect in these liquid samples different types of pathogens with high sensitivity and specificity. In this work, we propose a biosensing system in which the bacteria are labelled with streptavidin coated magnetic markers (MPs\u2014magnetic particles) forming compounds (MLBs\u2014magnetically labelled bacteria). Video microscopy in combination with a particle tracking software are used for their detection and quantification. When the liquid containing the MLBs is introduced into the developed, microfluidic platform, the MLBs are accelerated towards the outlet by means of a magnetic field gradient generated by integrated microconductors, which are sequentially switched ON and OFF by a microcontroller. The velocities of the MLBs and that of reference MPs, suspended in the same liquid in a parallel reference microfluidic channel, are calculated and compared in real time by a digital camera mounted on a conventional optical microscope in combination with a particle trajectory tracking software. The MLBs will be slower than the reference MPs due to the enhanced Stokes\u2019 drag force exerted on them, resulting from their greater volume and altered hydrodynamic shape. The results of the investigation showed that the parameters obtained from this method emerged as reliable predictors for E. coli concentrations.</p></article>", "keywords": ["0301 basic medicine", "0303 health sciences", "magnetophoresis", "magnetic microparticles", "Chemical technology", "magnetic labeling", "Microfluidics", "TP1-1185", "Biosensing Techniques", "Article", "6. Clean water", "particle tracking", "Magnetics", "03 medical and health sciences", "bacteria quantification", "13. Climate action", "Escherichia coli", "biosensing", "Water Microbiology"]}, "links": [{"href": "http://www.mdpi.com/1424-8220/18/7/2250/pdf"}, {"href": "https://doi.org/2867552234"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Sensors", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "2867552234", "name": "item", "description": "2867552234", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/2867552234"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2018-07-12T00:00:00Z"}}, {"id": "PMC6068504", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:25:01Z", "type": "Journal Article", "created": "2018-07-12", "title": "Biosensing System for Concentration Quantification of Magnetically Labeled E. coli in Water Samples", "description": "<?xml version='1.0' encoding='UTF-8'?><article><p>Bacterial contamination of water sources (e.g., lakes, rivers and springs) from waterborne bacteria is a crucial water safety issue and its prevention is of the utmost significance since it threatens the health and well-being of wildlife, livestock, and human populations and can lead to serious illness and even death. Rapid and multiplexed measurement of such waterborne pathogens is vital and the challenge is to instantly detect in these liquid samples different types of pathogens with high sensitivity and specificity. In this work, we propose a biosensing system in which the bacteria are labelled with streptavidin coated magnetic markers (MPs\u2014magnetic particles) forming compounds (MLBs\u2014magnetically labelled bacteria). Video microscopy in combination with a particle tracking software are used for their detection and quantification. When the liquid containing the MLBs is introduced into the developed, microfluidic platform, the MLBs are accelerated towards the outlet by means of a magnetic field gradient generated by integrated microconductors, which are sequentially switched ON and OFF by a microcontroller. The velocities of the MLBs and that of reference MPs, suspended in the same liquid in a parallel reference microfluidic channel, are calculated and compared in real time by a digital camera mounted on a conventional optical microscope in combination with a particle trajectory tracking software. The MLBs will be slower than the reference MPs due to the enhanced Stokes\u2019 drag force exerted on them, resulting from their greater volume and altered hydrodynamic shape. The results of the investigation showed that the parameters obtained from this method emerged as reliable predictors for E. coli concentrations.</p></article>", "keywords": ["0301 basic medicine", "0303 health sciences", "magnetophoresis", "magnetic microparticles", "Chemical technology", "magnetic labeling", "Microfluidics", "TP1-1185", "Biosensing Techniques", "Article", "6. Clean water", "particle tracking", "Magnetics", "03 medical and health sciences", "bacteria quantification", "13. Climate action", "Escherichia coli", "biosensing", "Water Microbiology"]}, "links": [{"href": "http://www.mdpi.com/1424-8220/18/7/2250/pdf"}, {"href": "https://doi.org/PMC6068504"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Sensors", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "PMC6068504", "name": "item", "description": "PMC6068504", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/PMC6068504"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2018-07-12T00:00:00Z"}}], "links": [{"rel": "self", "type": "application/geo+json", "title": "This document as GeoJSON", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=Magnetics&f=json", "hreflang": "en-US"}, {"rel": "alternate", "type": "text/html", "title": "This document as HTML", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=Magnetics&f=html", "hreflang": "en-US"}, {"rel": "collection", "type": "application/json", "title": "Collection URL", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main", "hreflang": "en-US"}, {"type": "application/geo+json", "rel": "first", "title": "items (first)", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=Magnetics&", "hreflang": "en-US"}, {"rel": "last", "type": "application/geo+json", "title": "items (last)", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=Magnetics&offset=6", "hreflang": "en-US"}], "numberMatched": 6, "numberReturned": 6, "distributedFeatures": [], "timeStamp": "2026-11-24T08:03:19.552109Z"}