{"type": "FeatureCollection", "features": [{"id": "10.1594/pangaea.972409", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:18:49Z", "type": "Dataset", "title": "Organic carbon content, stable carbon isotope ratios, and lignin phenol fingerprint of terrestrial material deposited at the paleo-delta of the Lena River at the transition to the Preboreal", "description": "The dataset was used to reconstruct the release of permafrost organic carbon from the watershed of the Lena River (Russia) between 11.1 and 11.7 calibrated thousand years Before Present (cal. kyr BP, Present = 1950 AD) and to model potential methane emissions from this carbon source. Data were obtained analyzing plant debris isolated from the low density fraction (&lt;1.8 g/cm3) of muddy sediments from the Piston Core 23 (PC23). The sediment core was retrieved in July 2014 in the mid/outer-shelf of the Laptev Sea shelf (76\u00b0 10' 15.6''N; 129\u00b0 20' 13.2''E, water depth of 56 m) during Leg 1 of the SWERUS-C3 expedition (Swedish-Russian-U.S. Arctic Ocean \u2013 Investigation of Climate-Cryosphere-Carbon interactions). Measurement of total organic carbon (TOC) and stable (d\u00b9\u00b3C) carbon isotopes were performed on 0.3 to 0.7 mg of samples on February 2022 using a Thermo DeltaQ isotope-ratio mass spectrometer (IRMS) coupled to a Thermo Flash 2000 Elemental Analyzer via a ConFlo IV interface at the at the Institute of Polar Sciences from the National Research Council of Italy (Bologna Section, Italy). The methodology for sample preparation followed Nieuwenhuize et al. (1994). Data on biomarkers (lignin phenols) were obtained extracting 2 to 3 mg of samples using a Microwave Accelerated Reaction System (MARS) 5 from CEM and following the methodology from Go\u00f1i &amp; Montgomery (2000). The extracts were analysed using a Agilent 7890A gas chromatograph (GC) coupled to an Agilent 5975C mass spectrometer to identify and quantify the compounds of interest. Biomarkers extraction and analyses were carried out on March 2022 in the organic chemistry laboratories of the Ente Nazionale Idrocarburi (ENI)-National Research Council (CNR) of Italy Joint Research Center 'Aldo Pontremoli' (Lecce, Italy). Stable isotope ratios and biomarkers were used to gain insights on the main vegetation source of the plant debris and (biomarkers only) to investigate the degradation state of the terrestrial material.", "keywords": ["5 dihydroxybenzoic acid per unit mass organic carbon", "p Coumaric acid per unit mass organic carbon", "SWERUS C3", "p-Hydroxybenzaldehyde per unit mass organic carbon", "Permafrost", "p Hydroxybenzaldehyde per unit mass organic carbon", "Latitude of event", "Arctic", "Gas chromatography (GC", " Agilent 7890A) equipped with a mass selective detector (MSD", " Agilent 5975C) and a flame ionization detector (FID", " Agilent 7683B)", "p-Hydroxybenzoic acid per unit mass organic carbon", "p-Hydroxyacetophenone/p-hydroxyl phenols ratio", "bottom maximum", "top min", "total", "Sample code/label", "p-Coumaric acid per unit mass organic carbon", "Vanillic acid vanillin ratio", "Deglaciation", "p-Hydroxyl phenols/vanillyl phenols ratio", "Depth", " sediment/rock", " bottom/maximum", "Syringic acid per unit mass organic carbon", "p-Hydroxyl phenols per unit mass organic carbon", "Sample code label", "p Hydroxyl phenols per unit mass organic carbon", "Depth", " top/min", "Acetovanillone per unit mass organic carbon", "Vanillic acid per unit mass organic carbon", "p Hydroxybenzoic acid per unit mass organic carbon", "p Hydroxyacetophenone per unit mass organic carbon", "Vanillic acid/vanillin ratio", "sediment rock", "p Hydroxyl phenols vanillyl phenols ratio", "Syringyl phenols vanillyl phenols ratio", "Earth System Research", "\u03b413C", "Ferulic acid per unit mass organic carbon", "Syringaldehyde per unit mass organic carbon", "Vanillin per unit mass organic carbon", "Methane", "Piston corer", "Isotope ratio mass spectrometer", " Thermo", " DeltaQ; coupled to an Elemental Analyzer; Thermo Flash 2000 via a ConFlo IV", "Longitude of event", "Syringyl phenols per unit mass organic carbon", "organic", "Syringic acid/syringaldehyde ratio", "Cinnamyl phenols/vanillyl phenols ratio", "DEPTH", " sediment/rock", "5 dihydroxybenzoic acid vanillyl phenols ratio", "Oden", "Cinnamyl phenols vanillyl phenols ratio", "Agilent 7683B", "p-Hydroxyacetophenone per unit mass organic carbon", "Date/Time of event", "Acetosyringone per unit mass organic carbon", "3", "5-dihydroxybenzoic acid per unit mass organic carbon", "Depth", "Event label", "Date Time of event", "p Hydroxyacetophenone p hydroxyl phenols ratio", "Vanillyl phenols per unit mass organic carbon", "Elevation of event", "Syringyl phenols/vanillyl phenols ratio", "Agilent 5975C and a flame ionization detector FID", "Carbon", "Cinnamyl phenols per unit mass organic carbon", "Agilent 7890A equipped with a mass selective detector MSD", "DEPTH", "Syringic acid syringaldehyde ratio", "3", "5-dihydroxybenzoic acid/vanillyl phenols ratio", "Gas chromatography GC", "Thermo", "SWERUS-C3", "Isotope ratio mass spectrometer", "DeltaQ coupled to an Elemental Analyzer Thermo Flash 2000 via a ConFlo IV", "Carbon", " organic", " total"], "contacts": [{"organization": "Sabino, Mathia, Gustafsson, \u00d6rjan, Wild, Birgit, Semiletov, Igor P, Dudarev, Oleg V, Ingrosso, Gianmarco, Tesi, Tommaso,", "roles": ["creator"]}]}, "links": [{"href": "https://doi.org/10.1594/pangaea.972409"}, {"rel": "self", "type": "application/geo+json", "title": "10.1594/pangaea.972409", "name": "item", "description": "10.1594/pangaea.972409", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/10.1594/pangaea.972409"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2024-01-01T00:00:00Z"}}, {"id": "10.3390/s6080648", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:19:47Z", "type": "Journal Article", "created": "2008-10-25", "title": "Solid State pH Sensor Based on Light Emitting Diodes (LED) As Detector Platform", "description": "<?xml version='1.0' encoding='UTF-8'?><article><p>A low-power, high sensitivity, very low-cost light emitting diode (LED)-baseddevice developed for low-cost sensor networks was modified with bromocresol greenmembrane to work as a solid-state pH sensor. In this approach, a reverse-biased LEDfunctioning as a photodiode is coupled with a second LED configured in conventionalemission mode. A simple timer circuit measures how long (in microsecond) it takes for thephotocurrent generated on the detector LED to discharge its capacitance from logic 1 ( 5 V)to logic 0 ( 1.7 V). The entire instrument provides an inherently digital output of lightintensity measurements for a few cents. A light dependent resistor (LDR) modified withsimilar sensor membrane was also used as a comparison method. Both the LED sensor andthe LDR sensor responded to various pH buffer solutions in a similar way to obtainsigmoidal curves expected of the dye. The pKa value obtained for the sensors was found toagree with the literature value.</p></article>", "keywords": ["670", "ph", "led", "TP1-1185", "02 engineering and technology", "01 natural sciences", "7. Clean energy", "solid-state pH sensor", "state", "platform", "Engineering", "sensor", "Physical Sciences and Mathematics", "emitting", "detector", "Chemical technology", "diodes", "colorimetric sensor", "pH sensing", "light dependent resistor.", "light emitting diode", "0104 chemical sciences", "optical sensing", "solid", "light", "0210 nano-technology"]}, "links": [{"href": "http://www.mdpi.com/1424-8220/6/8/848/pdf"}, {"href": "https://doi.org/10.3390/s6080648"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Sensors", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "10.3390/s6080648", "name": "item", "description": "10.3390/s6080648", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/10.3390/s6080648"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2006-08-23T00:00:00Z"}}, {"id": "2164696521", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:22:59Z", "type": "Journal Article", "created": "2008-10-25", "title": "Solid State pH Sensor Based on Light Emitting Diodes (LED) As Detector Platform", "description": "<?xml version='1.0' encoding='UTF-8'?><article><p>A low-power, high sensitivity, very low-cost light emitting diode (LED)-baseddevice developed for low-cost sensor networks was modified with bromocresol greenmembrane to work as a solid-state pH sensor. In this approach, a reverse-biased LEDfunctioning as a photodiode is coupled with a second LED configured in conventionalemission mode. A simple timer circuit measures how long (in microsecond) it takes for thephotocurrent generated on the detector LED to discharge its capacitance from logic 1 ( 5 V)to logic 0 ( 1.7 V). The entire instrument provides an inherently digital output of lightintensity measurements for a few cents. A light dependent resistor (LDR) modified withsimilar sensor membrane was also used as a comparison method. Both the LED sensor andthe LDR sensor responded to various pH buffer solutions in a similar way to obtainsigmoidal curves expected of the dye. The pKa value obtained for the sensors was found toagree with the literature value.</p></article>", "keywords": ["670", "ph", "led", "TP1-1185", "02 engineering and technology", "7. Clean energy", "01 natural sciences", "solid-state pH sensor", "state", "platform", "Engineering", "sensor", "Physical Sciences and Mathematics", "emitting", "detector", "Chemical technology", "diodes", "colorimetric sensor", "pH sensing", "light dependent resistor.", "light emitting diode", "0104 chemical sciences", "optical sensing", "solid", "light", "0210 nano-technology"]}, "links": [{"href": "http://www.mdpi.com/1424-8220/6/8/848/pdf"}, {"href": "https://doi.org/2164696521"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Sensors", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "2164696521", "name": "item", "description": "2164696521", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/2164696521"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2006-08-23T00:00:00Z"}}, {"id": "2311.04674", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:23:01Z", "type": "Journal Article", "created": "2024-04-09", "title": "Direct electrochemical reduction of graphene oxide thin film for aptamer-based selective and highly sensitive detection of matrix metalloproteinase 2", "description": "Simple and low-cost biosensing solutions are suitable for point-of-care applications aiming to overcome the gap between scientific concepts and technological production. To compete with sensitivity and selectivity of golden standards, such as liquid chromatography, the functionalization of biosensors is continuously optimized to enhance the signal and improve their performance, often leading to complex chemical assay development. In this research, the efforts are made on optimizing the methodology for electrochemical reduction of graphene oxide to produce thin film-modified gold electrodes. Under the employed specific conditions, 20 cycles of cyclic voltammetry (CV) are shown to be optimal for superior electrical activation of graphene oxide into electrochemically reduced graphene oxide (ERGO). This platform is further used to develop a matrix metalloproteinase 2 (MMP-2) biosensor, where specific anti-MMP2 aptamers are utilized as a biorecognition element. MMP-2 is a protein which is typically overexpressed in tumor tissues, with important roles in tumor invasion, metastasis as well as in tumor angiogenesis. Based on impedimetric measurements, we were able to detect as low as 3.32 pg/mL of MMP-2 in PBS with a dynamic range of 10 pg/mL - 10 ng/mL. Besides high specificity, ERGO-based aptasensor showed a potential of reuse due to demonstrated successful signal restoration after experimental detection of MMP-2.", "keywords": ["Physics - Instrumentation and Detectors", "FOS: Physical sciences", "Biomolecules (q-bio.BM)", "Physics - Applied Physics", "Electrochemical Techniques", "Biosensing Techniques", "02 engineering and technology", "Applied Physics (physics.app-ph)", "Instrumentation and Detectors (physics.ins-det)", "Aptamers", " Nucleotide", "01 natural sciences", "0104 chemical sciences", "03 medical and health sciences", "0302 clinical medicine", "Quantitative Biology - Biomolecules", "Limit of Detection", "FOS: Biological sciences", "Matrix Metalloproteinase 2", "Humans", "Graphite", "Gold", "0210 nano-technology", "Oxidation-Reduction", "Electrodes"]}, "links": [{"href": "https://doi.org/2311.04674"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Talanta", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "2311.04674", "name": "item", "description": "2311.04674", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/2311.04674"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2024-07-01T00:00:00Z"}}, {"id": "2307.16692", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:23:01Z", "type": "Journal Article", "created": "2023-11-10", "title": "Femtomolar detection of the heart failure biomarker NT-proBNP in artificial saliva using an immersible liquid-gated aptasensor with reduced graphene oxide", "description": "Measuring NT-proBNP biomarker is recommended for preliminary diagnostics of the heart failure. Recent studies suggest a possibility of early screening of biomarkers in saliva for non-invasive identification of cardiac diseases at the point-of-care. However, NT-proBNP concentrations in saliva can be thousand time lower than in blood plasma, going down to pg/mL level. To reach this level, we developed a label-free aptasensor based on a liquid-gated field effect transistor using a film of reduced graphene oxide monolayer (rGO-FET) with immobilized NT-proBNP specific aptamer. We found that, depending on ionic strength of tested solutions, there were different levels of correlation in responses of electrical parameters of the rGO-FET aptasensor, namely, the Dirac point shift and transconductance change. The correlation in response to NT-proBNP was high for 1.6 mM phosphate-buffered saline (PBS) and zero for 16 mM PBS in a wide range of analyte concentrations, varied from 1 fg/mL to 10 ng/mL. The effects of transconductance and Dirac point shift in PBS solutions of different concentrations are discussed. The biosensor exhibited a high sensitivity for both transconductance (2 uS/decade) and Dirac point shift (2.3 mV/decade) in diluted PBS with the linear range from 10 fg/mL to 1 pg/mL. The aptasensor performance has been also demonstrated in undiluted artificial saliva with the achieved limit of detection down to 41 fg/mL (~4.6 fM).", "keywords": ["Condensed Matter - Materials Science", "Physics - Instrumentation and Detectors", "Condensed Matter - Mesoscale and Nanoscale Physics", "Materials Science (cond-mat.mtrl-sci)", "FOS: Physical sciences", "Biomolecules (q-bio.BM)", "Physics - Applied Physics", "Applied Physics (physics.app-ph)", "Instrumentation and Detectors (physics.ins-det)", "02 engineering and technology", "01 natural sciences", "0104 chemical sciences", "Quantitative Biology - Biomolecules", "FOS: Biological sciences", "Mesoscale and Nanoscale Physics (cond-mat.mes-hall)", "0210 nano-technology"]}, "links": [{"href": "https://doi.org/2307.16692"}, {"rel": "related", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/Microchemical%20Journal", "name": "related record", "description": "related record", "type": "application/json"}, {"rel": "self", "type": "application/geo+json", "title": "2307.16692", "name": "item", "description": "2307.16692", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/2307.16692"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2024-01-01T00:00:00Z"}}, {"id": "2410.1244", "type": "Feature", "geometry": null, "properties": {"updated": "2026-10-06T16:23:02Z", "type": "Report", "title": "Surface plasmon resonance sensor based on a novel prism for the detection of a broad range of polymers", "description": "Open AccessMicroplastics are pervasive pollutants that pose threats to the environment and human health. Detecting them reliably represents a crucial step toward finding solutions. While traditional techniques like vibrational and mass spectroscopies are time-consuming and have limitations in analysing polymers with pigment additives, surface plasmon resonance (SPR) shows promise due to its high sensitivity and rapid detection capabilities.However, existing SPR methods rely on one output variable and fail to determine various microplastic parameters simultaneously. To address this uncertainty between size and polymer type, we propose a prism design that enables SPR resonance in a refractive index range of 1.402-1.56 RIU (Refractive Index Units) for polymer detection. Experimental verification of the prism's dynamic range using refractive index oils presented an agreement of 98.47% with theoretical analysis. Furthermore, we acquired SPR curves from ten different polymer types, including Nitrile, Viton and Tyre rubber. These results demonstrate SPR's potential to identify polymers and its ability to detect even pigmented materials, often challenging for other techniques. The imaging capabilities of the novel prism are presented, indicating its potential for future imaging of microplastics. Our approach holds promise for advancing microplastics analysis by enabling comprehensive assessment of particle parameters, such as polymer type, size, quantity and shape, and expanding the range of detectable polymer types.", "keywords": ["Physics - Instrumentation and Detectors", "FOS: Physical sciences", "Instrumentation and Detectors (physics.ins-det)"], "contacts": [{"organization": "Andrade, Natalia A. Gutierrez, Nie, Yunfeng, Meulebroeck, Wendy, Ottevaere, Heidi,", "roles": ["creator"]}]}, "links": [{"href": "https://doi.org/2410.1244"}, {"rel": "self", "type": "application/geo+json", "title": "2410.1244", "name": "item", "description": "2410.1244", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items/2410.1244"}, {"rel": "collection", "type": "application/json", "title": "Collection", "name": "collection", "description": "Collection", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main"}], "time": {"date": "2024-01-01T00:00:00Z"}}], "links": [{"rel": "self", "type": "application/geo+json", "title": "This document as GeoJSON", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=detector&f=json", "hreflang": "en-US"}, {"rel": "alternate", "type": "text/html", "title": "This document as HTML", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=detector&f=html", "hreflang": "en-US"}, {"rel": "collection", "type": "application/json", "title": "Collection URL", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main", "hreflang": "en-US"}, {"type": "application/geo+json", "rel": "first", "title": "items (first)", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=detector&", "hreflang": "en-US"}, {"rel": "last", "type": "application/geo+json", "title": "items (last)", "href": "https://repository.soilwise-he.eu/cat/collections/metadata:main/items?keywords=detector&offset=6", "hreflang": "en-US"}], "numberMatched": 6, "numberReturned": 6, "distributedFeatures": [], "timeStamp": "2026-11-23T07:08:52.792823Z"}